Structural Steel Design (6th Edition)
Structural Steel Design (6th Edition)
6th Edition
ISBN: 9780134589657
Author: Jack C. McCormac, Stephen F. Csernak
Publisher: PEARSON
Question
Book Icon
Chapter 14, Problem 14.1PFS
To determine

The LRFD design load and the ASD design loads for the given connection members.

Expert Solution & Answer
Check Mark

Answer to Problem 14.1PFS

  97.2k and 64.7k

Explanation of Solution

Given:

  Structural Steel Design (6th Edition), Chapter 14, Problem 14.1PFS

Calculation:

The ultimate load by LRFD is

  Pu=1.6PLPu=1.6(32)Pu=51.2kips

The factored moment is

  Mu=PuL4Mu=51.2( 40)4Mu=512kipsft

The factored shear force is

  Vu=Pu2Vu=51.22Vu=25.6kips

Refer Table 3-2 in the AISC steel construction manual.

Try W30×124

  ϕvVnxVu530kips26.5kipsϕbMpxMu1530kipsft512kipsft

The required moment of inertia is

  L1000=PLL348EI40×121000=32× ( 40×12 )348( 29000)II=5296.55in.4

Refer Table 3-3 in the AISC steel construction manual.

Try W30×124

  Ix=5360in.4>5296.55in.4

Hence, it’s safe.

The ultimate load by ASD is

  Pa=PLPa=32kips

The factored moment is

  Ma=PaL4Ma=32( 40)4Ma=320kipsft

The factored shear force is

  Va=Pa2Va=322Va=16kips

Refer Table 3-2 in the AISC steel construction manual.

Try W30×124

  VuΩVu353kips16kipsM pxΩbMu1020kipsft320kipsft

The required moment of inertia is

  L1000=PLL348EI40×121000=32× ( 40×12 )348( 29000)II=5296.55in.4

Refer Table 3-3 in the AISC steel construction manual.

Try W30×124

  Ix=5360in.4>5296.55in.4

By taking from the minimum values we obtained we get the allowable and safe loads.

Conclusion:

Therefore, the required loads by LRFD and ASD are 97.2k and 64.7k respectively.

Want to see more full solutions like this?

Subscribe now to access step-by-step solutions to millions of textbook problems written by subject matter experts!
Students have asked these similar questions
The connection shows a PL10X200 loaded in tension and welded to a gusset plate 10mm thick. Calculate the following, assuming A992 steel is used. Use U =0.85. The weld thickness is ómm and the electrode is E70 (485MPA). PL 10 X 200 350mm What is the allowable weld connection strength (kN)?
Determine the total LFRD design strength and the total ASD allowable strength of the 5/16 – in E70 fillet welds shown.
10 mm fillet welds Determine the design capacity of the welded lap steel connection shown below. All steel plates are 50X10mm dimension. Both fillet welds are 10mm E48XX SP, continuous across the full plate width. If the connection was tested to failure, which component would fail first.
Knowledge Booster
Background pattern image
Similar questions
SEE MORE QUESTIONS
Recommended textbooks for you
Text book image
Steel Design (Activate Learning with these NEW ti...
Civil Engineering
ISBN:9781337094740
Author:Segui, William T.
Publisher:Cengage Learning