A ferromagnetic core with a relative permeability of 2000 is shown in Figure. The dimensions are as shown in the diagram, and the depth of the core is 7 cm. The air gaps on the left and right sides of the core are 0.050 and 0.070 cm, respectively. If there are 300 turns in the coil wrapped around the center leg of the core and if the current in the coil is 1.0 A, what is the flux in each of the left, center, and right legs of the core? What is the flux density in each air gap?

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.9MCQ: Match the following: (i) Hysteresis loss (a) Can be redud by constructing the core with laminated...
icon
Related questions
Question
100%
constant.
15 cm
core depth = 15 cm
Problem 2
A ferromagnetic core with a relative
permeability of 2000 is shown in Figure.
The dimensions are as shown in the
diagram, and the depth of the core is 7
cm. The air gaps on the left and right
sides of the core are 0.050 and 0.070 cm,
respectively. If there are 300 turns in the
coil wrapped around the center leg of the
core and if the current in the coil is 1.0 A,
what is the flux in each of the left, center,
and right legs of the core? What is the
flux density in each air gap?
|7 cm
30 cm
7 cm
7 cm
30 cm
7 cm
30 cm
-0,05 cm
300 turns
0.07 cm
7 cm
1|Page
Transcribed Image Text:constant. 15 cm core depth = 15 cm Problem 2 A ferromagnetic core with a relative permeability of 2000 is shown in Figure. The dimensions are as shown in the diagram, and the depth of the core is 7 cm. The air gaps on the left and right sides of the core are 0.050 and 0.070 cm, respectively. If there are 300 turns in the coil wrapped around the center leg of the core and if the current in the coil is 1.0 A, what is the flux in each of the left, center, and right legs of the core? What is the flux density in each air gap? |7 cm 30 cm 7 cm 7 cm 30 cm 7 cm 30 cm -0,05 cm 300 turns 0.07 cm 7 cm 1|Page
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 5 steps with 1 images

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning